Ayuda
Ir al contenido

Dialnet


Estimation of Oxygen Uptake during Fast Running Using Accelerometry and Heart Rate

  • Autores: Barry W. Fudge, John Wilson, Chris Easton
  • Localización: Medicine & Science in Sports & exercise: Official Journal of the American College of Sports Medicine, ISSN 0195-9131, Vol. 39, Nº. 1, 2007, págs. 192-198
  • Idioma: inglés
  • Texto completo no disponible (Saber más ...)
  • Resumen
    • Previous investigations have reported that accelerometer counts plateau during running at increasingly faster speeds.

      Purpose: To assess whether biomechanical and/or device limitations cause this phenomenon and the feasibility of generating oxygen uptake (V?O2) prediction equations from the combined use of accelerometry and heart rate during walking and running.

      Methods: Sixteen endurance-trained subjects completed two exercise tests on a treadmill. The first was a continuous incremental test to volitional exhaustion to determine ventilatory threshold and peak V?O2. The second was a discontinuous incremental exercise test while walking (3, 5, and 7 km·h-1) and running (8, 10, 12, 14, 16, 18, and 20 km·h-1, or until volitional exhaustion). Subjects completed 3 min of exercise at each speed, followed by 3-5 min of recovery. Activity counts from uni- and triaxial accelerometers, heart rate, and gas exchange were measured throughout exercise.

      Results: All accelerometer outputs rose linearly with speed during walking. During running, uniaxial accelerometer outputs plateaued, whereas triaxial output rose linearly with speed up to and including 20 km·h-1. Prediction of V?O2 during walking and running using heart rate (R2 = 0.42 and 0.59, respectively), accelerometer counts (R2 = 0.48-0.83 and 0.76, respectively), the combined methodologies (R2 = 0.54-0.85 and 0.80, respectively), and the combined methodologies calibrated with individual data (R2 = 0.99-1.00 and 0.99, respectively) was completed by linear regression.

      Conclusions: Uni- and triaxial accelerometer outputs have a linear relationship with speed during walking. During running, uniaxial accelerometer outputs plateau because of the biomechanics of running, whereas triaxial accelerometer output has a linear relationship. The combined methodologies predict V?O2 better than either predictor alone; a subject's individually calibrated data further improves V?O2 estimation.


Fundación Dialnet

Dialnet Plus

  • Más información sobre Dialnet Plus

Opciones de compartir

Opciones de entorno