Ayuda
Ir al contenido

Dialnet


Resumen de Discrimination of edible olive oils by means of synchronous fluorescence spectroscopy with multivariate data analysis

A. Dankowska, M. Malecka, W. Kowalewski

  • The potential of fluorescence spectroscopy for the classification of olive oils was investigated. Synchronous fluorescence spectra were collected in the region of 240-700 nm with the wavelength intervals of 10, 30, 60 and 80 nm. Successive projection algorithm (SPA) was applied for the determination of representative wavelengths while the linear discriminant analysis (LDA) method was used to classify olive oils. The classification error of the method was low (0,9-6,4%) for measurements collected at all wavelength intervals. The best classification accuracy was obtained for synchronous fluorescence intensities acquired at 10 selected wavelengths with the wavelength interval equal to 10 nm.


Fundación Dialnet

Dialnet Plus

  • Más información sobre Dialnet Plus