The aim of this study was to analyze and compare electrocardiographic records of 50 horses American Miniature Horse, clinically healthy, obtained by conventional methods and computerized, to the standardization of the computerized method. The measures of duration and amplitude of waves and intervals and heart rate were analyzed in the leads of the frontal plane and base-apical lead. Differences about the duration of the P wave were found in I and aVL derivations, and QRS complex, in all derivations of the frontal plane. As for basis-apical derivation, there was no difference in the duration of the QT interval and the T wave and the amplitude of the S wave, therefore concluding that overestimation occurs in the duration of the QRS complex in computerized method and that due to inherent differences of each method, it becomes important the use of reference values for the computerized method also in the equine species
O objetivo deste estudo foi analisar e comparar os registros eletrocardiográficos de 50 equinos American Miniature Horse, clinicamente saudáveis, obtidos pelos métodos convencional e computadorizado, para a padronização do método informatizado. As medidas de duração e amplitude das ondas e intervalos e frequência cardíaca foram analisadas nas derivações do plano frontal e na derivação base-ápice. Diferenças quanto à duração da onda P, foram encontradas nas derivações I e aVL, e do complexo QRS, em todas as derivações do plano frontal. Quanto à derivação base-ápice, houve diferença na duração do intervalo QT e da onda T, assim como na amplitude da onda S. Concluiu-se, portanto, que ocorre superestimação da duração do complexo QRS no método computadorizado e que, devido às diferenças inerentes de cada método, torna-se importante a utilização de valores de referência para o método computadorizado também na espécie equina
© 2001-2024 Fundación Dialnet · Todos los derechos reservados