Ayuda
Ir al contenido

Dialnet


Influence of Soft Tissue Thickness on Peri-Implant Marginal Bone Loss: A Systematic Review and Meta-Analysis

    1. [1] University of Michigan–Ann Arbor

      University of Michigan–Ann Arbor

      City of Ann Arbor, Estados Unidos

    2. [2] Universidad de Granada

      Universidad de Granada

      Granada, España

  • Localización: Journal of periodontology, ISSN 0022-3492, Vol. 87, Nº. 6, 2016, págs. 690-699
  • Idioma: inglés
  • Enlaces
  • Resumen
    • Background: Multiple variables have been shown to affect early marginal bone loss (MBL). Among them, the location of the microgap with respect to the alveolar bone crest, occlusion, and use of a polished collar have traditionally been investigated as major contributory factors for this early remodeling. Recently, soft tissue thickness has also been investigated as a possible factor influencing this phenomenon. Hence, this study aims to further evaluate the influence of soft tissue thickness on early MBL around dental implants.

      Methods: Electronic and manual literature searches were performed by two independent reviewers in several databases, including Medline, EMBASE, and Cochrane Oral Health Group Trials Register, for articles up to May 2015 reporting soft tissue thickness at time of implant placement and MBL with ≥12-month follow-up. In addition, random effects meta-analyses of selected studies were applied to analyze the weighted mean difference (WMD) of MBL between groups of thick and thin peri-implant soft tissue. Metaregression was conducted to investigate any potential influences of confounding factors, i.e., platform switching design, cement-/screw-retained restoration, and flapped/flapless surgical techniques.

      Results: Eight articles were included in the systematic review, and five were included in the quantitative synthesis and meta-analyzed to examine the influence of tissue thickness on early MBL. Meta-analysis for the comparison of MBL among selected studies showed a WMD of −0.80 mm (95% confidence interval −1.18 to −0.42 mm) (P <0.0001), favoring the thick tissue group. Metaregression of the selected studies failed to demonstrate an association among MBL and confounding factors.

      Conclusion: The current study demonstrates that implants placed with an initially thicker peri-implant soft tissue have less radiographic MBL in the short term.


Fundación Dialnet

Dialnet Plus

  • Más información sobre Dialnet Plus

Opciones de compartir

Opciones de entorno