Resumen de Analysis of transient inductive interference in underground pipelines due to faults on nearby power lines

Jian Tang, Xiang Cui, Lei Qi, Tiebing Lu, Lin Li, Puxuan Zhu, Guang Yang, Weizhen Zhang

  • Purpose – The purpose of this paper is to present a method to calculate the transient induced voltages along the underground pipelines and analyze the transient interference generated in the pipelines due to the inductive coupling in the fault‐to‐ground condition of power lines in close proximity.

    Design/methodology/approach – Based on finite difference‐time domain method, an improved method is proposed to calculate transient inductive interference in underground metallic pipelines due to a fault in nearby power lines. The frequency‐dependent problem in the analysis of transient interference is solved in phase domain. Compared with the traditional method, the disposal of phase‐modal transformation matrices’ frequency‐dependent characteristic is avoided and the calculation is simplified by using vector fitting approach and recursive algorithm greatly in the proposed method.

    Findings – A novel improved method is proposed to calculate transient induced voltage distribution along underground metallic pipelines due to a fault in nearby power lines. Results show that the peak value of transient induced voltage at the most critical point is about 1.15 times of the magnitude in the steady state without the fault removed and the analysis of transient inductive interference is necessary in the fault‐to‐ground case of power lines.

    Practical implications – In order to mitigate the interference from power lines to nearby pipelines, pipelines should be good grounded and positioned as far away from the power line as possible. In high soil resistivity areas, the common corridor should be avoided.

    Originality/value – The paper presents a method to calculate the transient induced voltages along the underground pipelines and analyze the transient interference generated in the pipelines due to the inductive coupling in the fault‐to‐ground condition of nearby power lines. The proposed method is general and can also be applied to other transient interference studies such as crosstalk problems of communication networks and interference between power lines and aboveground pipelines or communication cables. Effects of various parameters upon the inductive interference generated in underground pipelines due to a fault in nearby power lines are analyzed to be a guide for controlling the inductive interference.