Measurement and modelling of rotational anomalous loss considering skin effect of electrical steel sheets

    1. [1] Tsinghua University

      Tsinghua University

      China

    2. [2] Hebei University of Technology

      Hebei University of Technology

      China

  • Localización: Compel: International journal for computation and mathematics in electrical and electronic engineering, ISSN 0332-1649, Vol. 36, Nº 6 (Special Issue: ICEF 2016), 2017, págs. 1750-1758
  • Idioma: inglés
  • Enlaces
  • Resumen
    • Purpose Due to existence of skin effect under rotational excitation, especially to high-frequency motors and power transformers run at the frequency of hundreds or even thousands of hertz, core losses will increase significantly, which may cause local overheating damage, and the efficiency and longevity will be decreased. The purpose of this paper is to accurately calculate the rotational anomalous loss in electrical steel sheets.

      Design/methodology/approach The influence of skin effect to rotational anomalous loss coefficient is described in detail. Based on the rotational core losses calculation approach, the transformed coefficient and parameters of rotational anomalous loss are determined in accordance with experimental data obtained by using 3D magnetic properties testing system. Then, a variable loss coefficient calculation model of rotational anomalous loss is built. Meanwhile, a separation of the total 2D elliptical rotation experimental core losses is worked out.

      Findings The two methods are analysed and compared qualitatively. It should be noted that the novel calculation model can be more effectively presented anomalous loss features. Moreover, quantitative comparisons between 2D elliptical rotation and alternating core losses have achieved beneficial conclusions.

      Originality/value Transformed rotational anomalous loss coefficient and parameters of electrical steel sheets considering skin effect are determined. Based on that, a novel calculation model evaluating 2D elliptical rotation anomalous loss is presented and verified based on the experimental measurement and the separation of the total 2D elliptical rotation core losses. The 2D elliptical rotation core losses separation method and quantitative comparison with alternating excitation are helpful to engineering application.