Antonio M. Pozo, Jose Juan Castro Torres, A. Manuel Rubiño López
Today, video cameras connected to frame grabbers or video capture cards (VCCs) are used in many applications such as traffic control, surveillance, medical systems or machine vision. In this work, we present a method for determining the spatial-frequency response of VCCs. This method is based on the modulation transfer function (MTF) determination from speckle patterns using a low-cost experimental setup. We have evaluated and compared three different VCCs. The three VCCs produce an amplification (boost) in the horizontal MTF in a different spatial-frequency range, also differing in the maximum amplification value
© 2001-2024 Fundación Dialnet · Todos los derechos reservados