Practical model of the axial magnetic field in the end region of large turbo-generators

    1. [1] Artois University

      Artois University

      Arrondissement d’Arras, Francia

    2. [2] EDF R and D, Francia
  • Localización: Compel: International journal for computation and mathematics in electrical and electronic engineering, ISSN 0332-1649, Vol. 38, Nº 4, 2019, págs. 1295-1305
  • Idioma: inglés
  • Enlaces
  • Resumen
    • Purpose – The axial magnetic field occurs in the end-region of large turbo-generators is known to induce hot points or voltages between laminations, that may cause insulation breakdown and thus stator faults.

      Design/methodology/approach – It is important to dispose of simple methods for estimating the axial flux rapidly with regard to the operating point of the machine.

      Findings – The authors provide a practical model of the axial magnetic field based on a simplified vector diagram. The parameters required to build the vector composition of the flux densities are assessed with a limited number of finite element method simulations of the whole end-region of the machine. These simulations were validated by an experimental test on a real turbo-generator. Then the axial flux density was .simply estimated for various operating points Originality/value – The originality of the paper concerns the practical model of the axial magnetic field based on a simplified vector diagram.