Resumen de Validity and Test-Retest Reliability of the Vmaxpro Sensor for Evaluation of Movement Velocity in the Deep Squat

Joshua F. Feuerbacher, Mats W. Jacobs, Boris Dragutinovic, Jan-Peter Goldmann, Sulin Cheng, Moritz Schumann

  • We aimed at assessing the validity and test-retest reliability of the inertial measurement unit-based Vmaxpro sensor compared with a Vicon 3D motion capture system and the T-Force sensor during an incremental 1-repetition maximum (1RM) test and at submaximal loads. Nineteen subjects reported to the laboratory for the 1RM test sessions, whereas 15 subjects carried out another 3 sessions consisting of 3 repetitions with 4 different intensities (30, 50, 70, and 90% of 1RM) to determine the intra- and interday reliability. The Vmaxpro sensor showed high validity (Vicon: R2 = 0.935; T-Force: R2 = 0.968) but an overestimation of the mean velocities (MVs) of 0.06 +/- 0.08 m[middle dot]s-1 and 0.06 +/- 0.06 m[middle dot]s-1 compared with Vicon and T-Force, respectively. Regression analysis indicated a systematic bias that is increasing with higher MVs. The intraclass correlation coefficients (ICCs) for Vmaxpro were moderate to high for intraday (ICC: 0.662-0.938; p <= 0.05) and for interday (ICC: 0.568-0.837; p <= 0.05) reliability, respectively. The Vmaxpro is a valid and reliable measurement device that can be used to monitor movement velocities within a training session. However, practitioners should be cautious when assessing movement velocities on separate days because of the moderate interday reliability.