Resumen de Microtensile Bond Strength Between Self-Adhesive Resin Cements and Resin Based Ceramic CAD/CAM Block

Meriç Berkman, Safa Tuncer, Neslihan Tekçe, Ferda Karabay, Mustafa Demirci

  • español

    Propósito: Evaluar y comparar la resistencia adhesiva microtensil (μTBS) de cuatro cementos de resina autoadhesivos diferentes con un bloque CAD / CAM de cerámica a base de resina, antes y después de 5.000 ciclos de termociclado. Materiales y métodos: cuatro cementos de resina de doble curado autoadhesivos; G-CEM LinkAce (GC EUROPE, Lovaina, Bélgica), RelyX U200 (3M ESPE, Seefeld, Alemania), Maxcem Elite (Kerr, CA, EE. UU.), TheraCem (Bisco, Schaumburg, EE. UU.) fueron aplicados a bloques Cerasmart CAD/CAM (GC EUROPE, Lovaina, Bélgica). Los bloques CAD/CAM se seccionaron en barras y se sometieron a pruebas µTBS a las 24 horas, y la otra mitad se sometió a pruebas después de 5000 ciclos térmicos. Los datos fueron probados por análisis de varianza unidireccional (p<0.05). Resultados: Los valores más altos de fuerza de unión se observaron en TheraCem, seguido de G-CEM LinkAce y RelyX U200, respectivamente (p<0.05). En la línea de base, G-CEM LinkAce, RelyX U200, Maxcem Elite mostró resultados estadísticamente similares. Después de 5.000 procesos de ciclo térmico, se observó una disminución significativa en los valores de resistencia de la unión de G-CEM LinkAce (p<0.05). Conclusión: entre los cementos adhesivos utilizados en el estudio, TheraCem mostró los valores más altos de resistencia de la unión micro-extensible tanto en la línea de base (24 h) como después de 5,000 procedimientos de envejecimiento térmico.

  • English

    Purpose: The objective of this study is to evaluate and compare the microtensile bond strength (μTBS) of four different self-adhesive resin cements to a resin-based ceramic CAD/CAM block, at the baseline, and after subjecting them to 5,000 thermo-cycles.Materials and Methods: Four self-adhesive dual-cured resin cements; G-CEM LinkAce (GC EUROPE, Leuven, Belgium), RelyX U200 (3M ESPE, Seefeld, Germany), Maxcem Elite (Kerr, CA, USA), TheraCem (Bisco, Schaumburg, USA) were applied to Cerasmart CAD/CAM blocks (GC EUROPE, Leuven, Belgium). CAD/CAM blocks were sectioned into sticks and subjected to µTBS tests at 24 hours, and the other half were subjected to tests after 5000 thermo-cycles. The data were tested by one-way variance analysis (p<0.05). Results: The highest bond strength values were observed in TheraCem, followed by G-CEM LinkAce and RelyX U200, respectively (p<0.05). At the baseline, G-CEM LinkAce, RelyX U200, and Maxcem Elite showed statistically similar results. After 5,000 thermal-cycles, a significant decrease was observed in the bond strength values of G-CEM LinkAce (p<0.05). Conclusion: Between the adhesive cements used in the study, TheraCem showed the highest micro-tensile bond strength values both in the baseline (24h) results, and after the 5,000 thermal-cycle aging procedures.


Fundación Dialnet

Dialnet Plus

  • Más información sobre Dialnet Plus