Ayuda
Ir al contenido

Dialnet


A single column chiroptical hplc batch analysis of ten aromatic alcohols

  • Autores: Marcelo A. Muñoz, María-Paz Orellana, Daniela Poblete
  • Localización: Journal of the Chilean Chemical Society (Boletín de la Sociedad Chilena de Química), ISSN-e 0717-6309, ISSN 0366-1644, Vol. 64, Nº. 2, 2019, págs. 4488-4491
  • Idioma: inglés
  • Enlaces
  • Resumen
    • The HPLC chiral resolution of ten chiral aromatic alcohols were screened using six different polysaccharides-based chiral stationary phases (CSP) and under four normal phase conditions, using UV absorbance as detection. The screening showed that all compounds can be baseline resolved in at least one of the tested conditions, being the cellulose-methylbenzoate CSP the one with the best performance by resolving the full set. Furthermore, the use of two chiroptical detectors, based in optical rotation and electronic circular dichroism, permitted the ascertain of the elution order for each of the baseline separations. Finally, several options for a single-column batch analysis, in which samples of all compounds are tested for enantiomeric excess and absolute configuration, are proposed to analyze samples from the asymmetric reduction of the corresponding ketones. These options vary in the number of injections, analysis time and reliability, and their choice will mostly depend on the hardware and standards availability.

Los metadatos del artículo han sido obtenidos de SciELO Chile

Fundación Dialnet

Dialnet Plus

  • Más información sobre Dialnet Plus

Opciones de compartir

Opciones de entorno