Ayuda
Ir al contenido

Dialnet


Características clínicas, esquemas de tratamiento, grado de control y variables asociadas a este en una cohorte de adultos con diabetes mellitus tipo 1 en un centro terciario

  • Autores: Bruno Grassi, Luciano Tapia, Ismael Aracena, Rocio Astudillo, Fernanda Kara, Margot Aliste, María Teresa Onetto, Pamela Matamala
  • Localización: Revista Médica de Chile, ISSN-e 0034-9887, Vol. 147, Nº. 4, 2019, págs. 451-457
  • Idioma: español
  • Títulos paralelos:
    • Clinical features and management of 205 adults with type 1 diabetes mellitus
  • Enlaces
  • Resumen
    • Background: Few studies have evaluated the details of insulin therapy for type 1 diabetes mellitus (T1D) in Chile. Aim: To describe clinical features and treatment details of adults with T1D and its association with metabolic control. Material and Methods: Review of medical records of patients with T1D treated in a clinical network. Demographic and clinical features, types and doses of insulin and glycated hemoglobin levels were registered. The use flash glucose monitors (FGM) and insulin pumps (CSII) were also recorded. Results: 205 records were reviewed, with T1d lasting 12 ± 10 years. Twenty six percent had hypothyroidism, 1% had celiac disease, 12% had hypertension, 20% had dyslipidemia; 13% had diabetic retinopathy, 2% had diabetic nephropathy, 8% had neuropathy and 2% cardiovascular diseases. Mean body mass index was 25 kg/ m2 and mean glycated hemoglobin was 8%. Eighty-two percent used multiple daily injections, 18% used CSII and 24% used FGM. As basal insulin, 35% used slow acting analogs and 65% used ultra-slow analogs. As rapid acting insulin, 69 patients used Lispro, 79 Aspart and 50 Glulisin. Bolus doses were calculated using only capillary glucose in 22%, while 78% also considered carbohydrate consumption. Variables significantly associated to better control were the use of carbohydrates for dosing rapid insulin (A1c 7,85% vs 8,59%, p = 0,008), use of CSII (A1c 7,36% vs 8,16%, p = 0,008), and basal dose < 0,4 U/kg (A1c 7,81% vs 8,58%, p = 0,003). There were no differences regarding insulin type or use of FGM. Conclusions: The use of formulas considering carbohydrates for dosing rapid insulin, use of infusion pumps and physiological doses of basal insulin are significantly associated with a better metabolic control in adults with T1d.

Los metadatos del artículo han sido obtenidos de SciELO Chile

Fundación Dialnet

Dialnet Plus

  • Más información sobre Dialnet Plus

Opciones de compartir

Opciones de entorno